IL-S100 keyence Sensor head
specification
Model | IL-S100 *1 | |||
Reference distance | 100 mm | |||
Measured distance | 70 ~ 130 mm | |||
light source | type | Red semiconductor laser wavelength: 655 nm (visible light) | ||
Laser class | Class 2 laser product (FDA(CDRH) Part1040.10 *2 , IEC 60825-1) | |||
output | 560 µW | |||
Spot diameter (at reference distance) | About 110 x 2700 µm | |||
Linearity | ±0.025% of F.S. (when used at 70 to 100 mm) *3 *4 ±0.07% of F.S. (when used at 70 to 130 mm) *3 *4 |
|||
Repeatability | 4µm *5 | |||
Sampling period | 0.33 / 1/2 / 5ms (4 steps variable) | |||
Operation indicator | Laser emission warning light: green LED, analog range indicator: orange LED, reference distance indicator: red/green LED | |||
Temperature characteristics | 0.03%ofF.S./℃ *4 | |||
Environmental resistance | Protective structure | IP67 | ||
Pollution degree | 3 | |||
Ambient illuminance | Incandescent lamp: 10,000 lux *6 | |||
Ambient temperature | -10 to +50 °C (no condensation or freezing) | |||
Ambient humidity | 35 to 85% RH (no condensation) | |||
Vibration resistance | 10 to 55 Hz, 1.5 mm double amplitude, 2 hours in each direction of X, Y and Z | |||
Material | Body case: PBT, metal part: SUS304, packing: NBR, lens cover: glass, cable: PVC | |||
mass | About 75 g | |||
*1 Cannot be used with amplifier units purchased before August 16, 2011. *2 Classified according to IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No.50. I am. *3 The value when measuring our standard object (white diffuse object). *4 The FS of each model is as shown on the right. IL-S025: ±5 mm, IL-S065: ±10 mm, IL-S100: ±30 mm *5 Value when measuring our standard object (white diffuse object) at the reference distance with a sampling period of 1 ms and an average count of 128 times. is. *6 The value when the sampling period is set to 2 ms or 5 ms. |