D4C-3202 Omron limit switch
Shape / structure | Vertical vertical type |
---|---|
lifespan | General form |
Actuator | Roller · Plunger type φ12 × 5 stainless steel type sintered roller |
Electrical rating | DC 30 V 4 A |
Rated frequency | 50/60 Hz |
Contact configuration | 1c |
load | General load |
Switching ability (DC) / no inductive load | Rated load: 2A (NC) 2A (NO) Rated voltage: DC 30 V / resistance load: 4 A (NC) 4 A (NO) |
Switching capacity (DC) / inductive load | Rated voltage: DC 30 V / Inductive load: 3 A (NC) 3 A (NO) / Motor load: 3 A (NC) 3 A (NO) |
Allowable inrush current | Normally closed circuit (NC): 20 A Always open circuit (NO): 10 A |
Protection circuit | Electric shock protection class: Class I (with ground wire) Short circuit protection device: 10 A Fuse type gI or gG (IEC 60269) |
Operation indicator light | LED (lighting when not operating) Voltage: DC 30 V Leakage current: Approx. 1.7 mA |
Ground terminal | With ground wire |
Cable specification | VCTF oil resistant cable 3 m |
Ambient temperature range | At use: -10 to 70 ° C (but not freezing) |
Ambient humidity range | At use: 35 to 95% RH (with no condensation) |
Allowable operation frequency (mechanical) | 120 times / min or less |
---|---|
Allowable operation frequency (electrical) | 30 times / minute or less |
Contact resistance (Initial value) | 300 mΩ or less |
Insulation resistance | 100 MΩ or more (DC 500 V mega) |
Withstand voltage | Between terminals with the same polarity: AC 1000 V 50/60 Hz 1 min Between charging metal part and ground: AC 1500 V 50/60 Hz 1 min Between each terminal and non-charging metal part: AC 1500 V 50/60 Hz 1 min |
Impulse withstand voltage | Between charging metal part and ground: 2.5 kV Between each terminal and non-charging metal part: 2.5 kV |
Durability (mechanical) | 10 million times or more (temperature and humidity condition: 5 to 35 ° C., 40 to 70% RH) |
Vibration proof (malfunction) | 10 to 55 Hz Double amplitude 1.5 mm |
Impact resistance (durability) | Up to 1000 m / s ** 2 |
Impact resistance (malfunction) | Maximum 500 m / s ** 2 |
Pollution degree | 3 (EN 60947-5-1) |
Protective structure | IP 67 |
Power required for operation (OF) | Standard value maximum 11.77 N |
---|---|
The power of return (RF) | Standard value minimum 4.41N |
Movement to action (PT) | Standard value maximum 1.8 mm |
Motion after movement (OT) | Standard value minimum 3 mm |
Hysteresis movement (MD) | Standard value maximum 0.2 mm |
Operating position (OP) | Standard value 28.5 ± 1 mm |
Reviews