D4C-1520 Omron limit switch
Shape / structure | Vertical vertical type |
---|---|
lifespan | General form |
Actuator | Roller and lever type φ 17.5 × 7 stainless steel sintered roller R 38 |
Electric rating | AC 250 V 5 A DC 30 V 4 A |
Rated frequency | 50/60 Hz |
Contact configuration | 1c |
load | General load |
Switching ability (AC) / no inductive load | Rated load: 1.5 A (NC) 0.7 A (NO) Rated voltage: AC 250 V / resistance load: 5 A (NC) 5 A (NO) / lamp load: 5 A (NC) 1A (NC) 0.5 A (NO) |
Switching capacity (AC) / inductive load | Rated voltage: AC 125V / Inductive load: 3A (NC) 3A (NO) / Motor load: 2.5A (NC) 1.3A (NO) Rated voltage: AC 250V / Inductive load: 2A (NC) 2A (NO) 1.5 A (NC) 0.8 A (NO) |
Switching ability (DC) / no inductive load | Rated load: 2A (NC) 2A (NO) Rated voltage: DC 14 V / resistance load: 5 A (NC) 5 A (NO) / lamp load: 2 A NC) 2A (NO) rated voltage: DC30V / resistive load: 4A (NC) 4A (NO ) / lamp load: 2A (NC) 2A (NO ) rated voltage: DC125V / resistive load: 0.4A (NC) 0.4A ( (NO) / lamp load: 0.05 A (NC) 0.05 A (NO) Rated voltage: DC 250 V / resistance load: 0.2 A (NC) 0.2 A (NO) / lamp load: 0.03 A (NC) |
Switching capacity (DC) / inductive load | Voltage rating: 4 A (NC) 4 A (NC) 4 A (NO) / Motor load: 3 A (NO) Rated voltage: DC 8 V / Inductive load: 5 A (NC) 4 A NC 3A (NO) Rated voltage: DC 125 V / Inductive load: 0.4 A (NC) 0.4 A ( NO) Rated voltage: DC 30 V / Inductive load: 3 A (NC) (NO) / Motor load: 0.05 A (NC) 0.05 A (NO) Rated voltage: DC 250 V / Inductive load: 0.2 A (NC) 0.2 A (NO) / Motor load: 0.03 A (NC) |
Allowable inrush current | Normally closed circuit (NC): 20 A Always open circuit (NO): 10 A |
Protection circuit | Electric shock protection class: Class I (with ground wire) Short circuit protection device: 10 A Fuse type gI or gG (IEC 60269) |
Ground terminal | With ground wire |
Cable specification | VCTF 5 m |
Ambient temperature range | When used: -10 to 70 ℃ (However, do not freeze) |
Ambient humidity range | When used: 35 to 95% RH (with no condensation) |
Allowable operating speed | 1 mm / s to 1 m / s |
---|---|
Allowable operation frequency (mechanical) | 120 times / min or less |
Allowable operation frequency (electrical) | 30 times / minute or less |
Contact resistance (Initial value) | 400 mΩ or less |
Insulation resistance | 100 MΩ or more (DC 500 V Mega) |
Withstand voltage | Between terminals with the same polarity: AC 1000 V 50/60 Hz 1 min Between charging metal part and earth: AC 1500 V 50/60 Hz 1 min Between each terminal and non-charging metal part: AC 1500 V 50/60 Hz 1 min |
Impulse withstand voltage | Between charging metal part and ground: 2.5 kV Between each terminal and non-charging metal part: 2.5 kV |
Durability (mechanical) | 10 million times or more (temperature and humidity condition: 5 to 35 ° C., 40 to 70% RH) |
Durability (electrical) | 200,000 cycles or more (AC 125 V 5 A) (temperature, humidity condition: 5 to 35 ° C., 40 to 70% RH) |
Vibration proof (malfunction) | 10 to 55 Hz Double amplitude 1.5 mm |
Impact resistance (durability) | Up to 1000 m / s ** 2 |
Impact resistance (malfunction) | Maximum 500 m / s ** 2 |
Pollution degree | 3 (EN 60947-5-1) |
Protective structure | IP 67 |
Power required for operation (OF) | Standard value Maximum 5.69 N |
---|---|
The power of return (RF) | Standard value Minimum 1.47 N |
Movement to action (PT) | Standard value Maximum 25 ° |
Motion after movement (OT) | Standard value Minimum 40 ° |
Hysteresis movement (MD) | Standard value Maximum 3 ° |