E3C-LDA
Sensor Heads
Sensing method |
Appearance | Beam shape | Model | Remarks |
---|---|---|---|---|
Diffuse- reflective |
SpotSpot (variable) |
E3C-LD11 2M | Mounting a Beam Unit (sold separately) allows the use of line and area beams. |
|
Line (variable) |
E3C-LD21 2M | This model number is for the set consisting of the E39-P11 mounted to the E3C-LD11. |
||
Area (variable) |
E3C-LD31 2M | This model number is for the set consisting of the E39-P21 mounted to the E3C-LD11. |
||
Coaxial Retro-reflective |
Spot (variable) |
E3C-LR11* 2M | Mounting a Beam Unit (order separately) enables the use of line and area beams. |
|
Spot (2.0-mm fixed dia.) |
E3C-LR12* 2M | — |
Amplifier Units
Pre-wired Amplifier Units
Item | Appearance | Functions | Model | ||
---|---|---|---|---|---|
NPN output | PNP output | ||||
Advanced models |
External-input models |
Remote setting Counter Differential operation |
E3C-LDA21 2M | E3C-LDA51 2M | |
Twin-output models |
Area output Self-diagnosis Differential operation |
E3C-LDA11 2M | E3C-LDA41 2M | ||
ATC function | ATC (Active Threshold Control) |
E3C-LDA11AT 2M | E3C-LDA41AT 2M | ||
Analog output | Analog output | E3C-LDA11AN 2M | E3C-LDA41AN 2M |
Amplifier Units with Wire-saving Connectors
Item | Appearance | Functions | Model | ||
---|---|---|---|---|---|
NPN output | PNP output | ||||
Advanced models |
External-input models | Remote setting Counter Differential operation |
E3C-LDA7 * | E3C-LDA9 * | |
Twin-output models | Area output Self-diagnosis Differential operation |
E3C-LDA6 * | E3C-LDA8 * | ||
ATC function | ATC (Active Threshold Control) | E3C-LDA6AT | E3C-LDA8AT |
Amplifier Unit with Connector for Sensor Communications Unit (for EtherCAT and CompoNet)
Item | Appearance | Functions | Model | Applicable Sensor Communications Unit |
|
---|---|---|---|---|---|
Advanced models |
Twin-output models | Area output Self-diagnosis Differential operation |
E3C-LDA0 | E3X-ECT | |
E3X-CRT |
Accessories (Order Separately)
Wire-saving connectors (Required for models for Wire-saving Connectors.)
Item | Appearance | Cable length | No. of conductors | Model |
---|---|---|---|---|
Master Connector | 2 m | 4 | E3X-CN21 | |
Slave Connector | 2 | E3X-CN22 |
Ordering Precaution for Amplifier Units with Wire-saving Connectors
Amplifier Unit | Applicable Connector (order separately) | |||
---|---|---|---|---|
Model | NPN output | PNP output | Master Connector | Slave Connector |
Advanced models |
E3C-LDA6 | E3C-LDA8 | E3X-CN21 | E3X-CN22 |
E3C-LDA7 | E3C-LDA9 | |||
E3C-LDA6AT | E3C-LDA8AT |
When Using 5 Amplifier Units
Mobile Console
Appearance | Model | Remarks |
---|---|---|
E3X-MC11-SV2 (model number of set) |
Mobile Console with Head, Cable, and AC adapter provided as accessories |
|
E3X-MC11-C1-SV2 | Mobile Console | |
E3X-MC11-H1 | Head | |
E39-Z12-1 | Cable (1.5 m) |
eam Unit (for E3C-LD11/LR11)
Applicable Sensor Head | Appearance | Focus | Model |
---|---|---|---|
E3C-LD11 | Line | E39-P11 | |
Area | E39-P21 | ||
E3C-LR11 | Line | E39-P31 | |
Area | E39-P41 |
Reflectors (Required when using retro-reflective models)
Type | Appearance | Model |
---|---|---|
Standard Effective area: 23 × 23 mm * |
E39-R12 | |
Standard Effective area: 7 × 7 mm * |
E39-R13 | |
Transparent object detection Effective area: 23 × 23 mm * |
E39-R14 | |
Sheet (cuttable) Effective area: 195 × 22 mm |
E39-RS4 | |
Sheet (cuttable) Effective area: 108 × 46 mm |
E39-RS5 |
Mounting Bracket
Appearance | Model | Quantity |
---|---|---|
E39-L143 | 1 |
End Plate
Appearance | Model | Quantity |
---|---|---|
PFP-M | 1 |
E3NC-L
Sensor Heads: E3NC-L Compact Laser Sensor Series
Sensing method |
Appearance | Beam shape | Sensing distance |
Laser class |
Cable length | Model |
---|---|---|---|---|---|---|
Coaxial Retro- reflective with MSR function |
Spot | 8 m * | Class 1 | 2 m | E3NC-LH03 2M | |
5 m | E3NC-LH03 5M | |||||
Diffuse- reflective |
Variable spot | 1.2 m | 2 m | E3NC-LH02 2M | ||
5 m | E3NC-LH02 5M | |||||
Limited- reflective |
Spot | 70±15 mm | 2 m | E3NC-LH01 2M | ||
5 m | E3NC-LH01 5M |
Amplifier Units: E3NC-L Compact Laser Sensor Series
Connecting method | Appearance | Inputs/outputs | Model | |
---|---|---|---|---|
NPN output | PNP output | |||
Pre-wired (2 m) | 2 outputs + 1 input | E3NC-LA21 2M | E3NC-LA51 2M | |
Wire-saving Connector | 1 output + 1 input | E3NC-LA7 | E3NC-LA9 | |
M8 Connector | 1 output + 1 input | E3NC-LA24 | E3NC-LA54 | |
Connector for Sensor Communications Unit * |
— | E3NC-LA0 |
E3NC-S
Sensor Heads
Sensing method |
Appearance | Beam shape | Measurement range |
Laser class |
Cable length | Model |
---|---|---|---|---|---|---|
Distance- settable |
Spot | 35 to 250 mm | Class 2 | 2 m | E3NC-SH250H 2M | |
Class 1 | 2 m | E3NC-SH250 2M | ||||
35 to 100 mm | 2 m | E3NC-SH100 2M |
Amplifier Units
Connecting method | Appearance | Inputs/outputs | Model | |
---|---|---|---|---|
NPN output | PNP output | |||
Pre-wired (2 m) | 2 outputs + 1 input | E3NC-SA21 2M | E3NC-SA51 2M | |
Wire-saving Connector | 1 output + 1 input | E3NC-SA7 | E3NC-SA9 | |
M8 Connector | 1 output + 1 input | E3NC-SA24 | E3NC-SA54 | |
Connector for Sensor Communications Unit * |
— | E3NC-SA0 |